@rohanpaul_ai· @rohanpaul_ai · X·· 2026-09-03AI 评分40
AI 导读

Sam Altman 称 ChatGPT 每 3.8 万次查询的耗水量,相当于加州生产一颗杏仁的用水量。他表示数据中心早已不再使用蒸发冷却,现代大型数据中心的用水量仅相当于一栋办公楼里人员使用洗手间和厕所的水平。

正文

Sam Altman explains how little water AI uses.

"For every 38,000 ChatGPT queries, that is the same amount of water that is used in the production of a single almond in California.

It is true that data centers at one point used evaporative cooling, but they have not done that in a long time. If you look at a modern, very large data center, it uses the equivalent amount of water as an office building, in terms of people running the sinks, toilets, and whatever."

----

From "Sources Podcast and Alex Heath (@alexeheath )" YouTube channel, (full video link in comment)

引用@rohanpaul_ai@rohanpaul_ai
Satya Nadella: Microsoft’s latest Wisconsin AI data center keeps yearly water consumption no higher than that of 1 local restaurant. "The cooling loop is filled once and the data centre can operate effectively with zero water consumption. Daily water usage across a year is roughly equivalent to what a single restaurant would use" The mechanism is mainly about replacing evaporative cooling with closed-loop direct-to-chip liquid cooling, so water moves like coolant inside a sealed machine rather than being boiled off into the air. Hot GB200-class AI racks produce too much heat for normal air cooling, so cold liquid is pushed through pipes into the servers and across metal cold plates touching the hottest chips. The liquid enters the rack cool, absorbs heat from the chips through cold plates, then exits the rack at a higher temperature and carries that heat through pipes to a huge cooling system outside the compute floor. Microsoft says Fairwater sends that hot water to cooling “fins” beside the datacenter, where 172 20-foot fans blow air across the fins and dump the heat into the outside air. The important detail is that the air cools the water through metal surfaces, so the water does not need to evaporate the way many older datacenters use cooling towers. The cooled liquid then returns to the servers, repeats the loop, and keeps absorbing heat from the chips. In older data centers, heat is often removed partly through cooling towers. Hot water meets moving air, some water evaporates, and that phase change carries heat away. Effective, but it consumes fresh water continuously. But Firwater is a closed loop because the same coolant keeps circulating through sealed pipes: it absorbs heat from the chips, releases that heat through radiator-like fins, then flows back to the chips again. For Wisconsin Fairwater, Microsoft says more than 90% of the facility uses closed-loop liquid cooling, while the remaining portion uses outside air and switches to water only on the hottest days. ---- From "Microsoft" YouTube channel, (link in comment)
在 X 查看被引用的帖子

来源:@rohanpaul_ai · x.com