Satya Nadella:微软最新的威斯康星AI数据中心年用水量不超过当地一家餐厅。 "冷却回路一次性注满,数据中心即可在零水耗下有效运行。全年日均用水量大约相当于一家餐厅的用量" 其机制主要是用闭环芯片直连液冷替代蒸发冷却,水作为冷却液在密封机器内部循环,而非蒸发到空气中。 GB200级AI机架发热量太大,普通风冷无法应对,因此冷液通过管道送入服务器,流经接触最热芯片的金属冷板。 液体低温进入机架,通过冷板吸收芯片热量,然后以更高温度离开机架,通过管道将热量输送到计算区外的大型冷却系统。 微软表示,Fairwater将热水送往数据中心旁的冷却"鳍片",172个20英尺风扇将空气吹过鳍片,把热量排入室外空气。 关键细节在于,空气通过金属表面冷却水,因此水不需要像许多老式数据中心使用冷却塔那样蒸发。 冷却后的液体返回服务器,循环往复,持续吸收芯片热量。 在老式数据中心中,热量通常部分通过冷却塔排出。热水遇到流动空气,部分水…
正文
https://t.co/3GpDPsjV97
Satya Nadella: Microsoft’s latest Wisconsin AI data center keeps yearly water consumption no higher than that of 1 local restaurant. "The cooling loop is filled once and the data centre can operate effectively with zero water consumption. Daily water usage across a year is roughly equivalent to what a single restaurant would use" The mechanism is mainly about replacing evaporative cooling with closed-loop direct-to-chip liquid cooling, so water moves like coolant inside a sealed machine rather than being boiled off into the air. Hot GB200-class AI racks produce too much heat for normal air cooling, so cold liquid is pushed through pipes into the servers and across metal cold plates touching the hottest chips. The liquid enters the rack cool, absorbs heat from the chips through cold plates, then exits the rack at a higher temperature and carries that heat through pipes to a huge cooling system outside the compute floor. Microsoft says Fairwater sends that hot water to cooling “fins” beside the datacenter, where 172 20-foot fans blow air across the fins and dump the heat into the outside air. The important detail is that the air cools the water through metal surfaces, so the water does not need to evaporate the way many older datacenters use cooling towers. The cooled liquid then returns to the servers, repeats the loop, and keeps absorbing heat from the chips. In older data centers, heat is often removed partly through cooling towers. Hot water meets moving air, some water evaporates, and that phase change carries heat away. Effective, but it consumes fresh water continuously. But Firwater is a closed loop because the same coolant keeps circulating through sealed pipes: it absorbs heat from the chips, releases that heat through radiator-like fins, then flows back to the chips again. For Wisconsin Fairwater, Microsoft says more than 90% of the facility uses closed-loop liquid cooling, while the remaining portion uses outside air and switches to water only on the hottest days. ---- From "Microsoft" YouTube channel, (link in comment)在 X 查看被引用的帖子
来源:@rohanpaul_ai · x.com